Inspection disposition
- Capture: unit Q-03
- Candidate: bright linear feature
- Reference: changed lamp angle
- Physical review: no fracture confirmed
- Action: check camera calibration before adjusting thresholds
- Reviewer: line quality engineer
Inspect the review notes
Include clean units in the sample supplied for review, so inspectors see the normal variation and can assess unnecessary referrals. A collection containing only images already flagged by the system gives little evidence about the defects it missed entirely.
How the work moves
Follow the operating sequence
Gather the evidence
Collect images across cameras, shifts, material finishes and lighting conditions. Link each inspection to the physical lot and the operator's verified finding. Specify how a reviewer records an image that cannot support a reliable judgment.
Prepare the action
Normalize image capture at a fixed inspection position. Present the candidate defect location next to a known reference sample. A quality engineer can mark a real defect, a reflection or an unusable image. Keep that decision separate from changing the line's operating state.
Route the exception
A glossy finish produces a light stripe resembling a crack. It appears in the same location across unrelated units after a lamp change. The review batch includes both material examples and a calibration image so maintenance can investigate the camera setup.
Compare a complete record with an exception
Source and permissions
Collect images across cameras, shifts, material finishes and lighting conditions. Link each inspection to the physical lot and the operator's verified finding. Specify how a reviewer records an image that cannot support a reliable judgment.
Exception to rehearse
A glossy finish produces a light stripe resembling a crack. It appears in the same location across unrelated units after a lamp change. The review batch includes both material examples and a calibration image so maintenance can investigate the camera setup.
Test the workflow on real operating conditions
Reserve examples by production run so near-identical frames from the same unit cannot appear in training and evaluation. Review misses by material and defect class, track referrals per shift and inspect the effects of a changed camera angle.
Keep a dated visual reference for each reviewed condition. A camera that moves by a few centimetres can produce an apparent jump in defects across every item. Record ambient changes alongside alerts and route a calibration problem to maintenance and uncertain images to quality review.
Agree who takes ownership
What Opergens delivers
An inspection pilot, an annotated reference set, a reviewer queue for uncertain images and a plan for recalibration after a line change.
What the operator verifies
Quality engineers compare missed defects and unnecessary referrals separately for each class. Operators retain control of line decisions during the assessment.

- Gather the evidence
- Collect images across cameras, shifts, material finishes and lighting conditions. Link each inspection to the physical lot and the operator's verified finding. Specify how a reviewer records an image that cannot support a reliable judgment.
- Prepare the action
- Normalize image capture at a fixed inspection position. Present the candidate defect location next to a known reference sample. A quality engineer can mark a real defect, a reflection or an unusable image. Keep that decision separate from changing the line's operating state.
- Route the exception
- A glossy finish produces a light stripe resembling a crack. It appears in the same location across unrelated units after a lamp change. The review batch includes both material examples and a calibration image so maintenance can investigate the camera setup.